Nov 20, 2025 Leave a message

A Simple Guide to Control Valve Data Sheets

 

 

1. Overview Concepts

 

TAG No: Unique factory equipment identifier, e.g., FV-1001

Quantity: Procurement/installation count of this model, e.g., 1 unit

P & ID No: Pipeline number in P&ID for location positioning

Line Size: Pipeline nominal diameter, wall thickness etc., supplement with engineering drawings

Line Material: Pipeline material such as carbon steel, stainless steel

Service: Used for transporting media e.g., sodium chloride, sodium sulfate solutions

Project Name/Contract No/Unit Name: Identification information of project, contract and unit

 

 

2. Fluid and Operating Condition Concepts

 

Fluid Name: Medium through control valve, e.g., sodium chloride, sodium sulfate solutions

Fluid State: Physical state of medium, e.g., Liquid

Operation Temp: Medium temperature at control valve, max/normal/min e.g., 25℃

Flow Rate Unit: Measurement unit of flow rate, e.g., m³/H

Flow Rate: Flow range through control valve, max 8 m³/H, normal 5 m³/day, min 2 m³/day

Pressure Unit: Measurement unit of pressure, e.g., MPa(g)

Inlet Pressure: Pressure at control valve inlet, max/normal/min e.g., 0.3 MPa(g)

Outlet Pressure: Pressure at control valve outlet, max/normal/min e.g., 0.28 MPa(g)

Differential Pressure: Difference between inlet and outlet pressure, 0.02 MPa(g)

OP. Gr.: Relative density of medium under operating conditions, e.g., 1.010

ST Density: Medium density under standard conditions, e.g., 1010 Kg/m³

Calculated KV Value: Flow coefficient, max 17.98, normal 11.24, min 4.49

Valve Travel (%): Valve core opening degree, max 90.31%, normal 76.49%, min 49.55%

Noise Level: Operation noise intensity, e.g., ≤80 dB

 

 

3. Valve Body Component Concepts

 

Type: Globe Valve, suitable for medium-low pressure with small leakage

Model No.: Manufacturer's model designation, e.g., ZJHP

Body Size (DN): Nominal diameter of valve body, e.g., 40

Port Size (dN): Nominal diameter of valve seat, e.g., 40

Rated KV Value: Flow coefficient at full open, e.g., KV=25

Nominal Pressure (Rating): Pressure resistance grade, e.g., PN10

Connection: Flange standard, e.g., HG/T20592-2009 RF

 

Material:

Body: e.g., 4A

Plug, Seat, Stem: e.g., 2205 duplex stainless steel

 

Leakage Class: Sealing performance grade, e.g., ANSI B16.104-IV

Flow Characteristic: EQ % equal percentage characteristic for precise regulation

Bonnet Type: Normal Temperature Type, applicable to -29~200℃

Packing: PTFE with chemical corrosion and high temperature resistance

Action Type: Air-to-Open, auto-closes on air supply failure

 

 

4. Actuator Concepts

 

Type: Multi-Spring Pneumatic Diaphragm Type, compact with stable output

Model No.: Manufacturer's model designation, e.g., ZHB23

Travel (mm): Maximum moving distance of valve core, e.g., 25 mm

Air Supply Pressure (MPa): Driving air source pressure, e.g., 0.3 MPa

Spring Range (KPa): Pressure adjustment range, e.g., 80-240 KPa

Input Signal: Control electrical signal, usually 4-20mA 

Handwheel Mechanism: TOP-mounted for manual operation

Shut-off Differential Pressure (MPa): Maximum withstand pressure when closed, e.g., 1 MPa

 

 

5. Positioner and Solenoid Valve Concepts

 

Positioner: Precise control device, match air supply pressure and input signal

Solenoid Valve: Quick cut-off/conduct valve, specify model, voltage and interface

Air Regulator (AIR SET): Reduces air source pressure, dimensions L=222, H=455, D=140, D1=100, n-d=4-Φ18

 

 

6. Special Requirement Concepts

 

Special Inspection: Additional inspection requirements for control valve

Copper-Free Requirement: Prohibition of copper materials 

Specified Coating Color: Anti-corrosion coating color requirement

Oil and Water Removal: Air source treatment requirement for pneumatic valves

Tropical or Frigid Zone Application: Adaptability to extreme temperature environments

Sand and Dust Proof: Dust-proof structure requirement

High Corrosion Resistance: Resistance to highly corrosive media

High Frequency Operation: Requirement for frequent switching

Open/Close Time: Full opening/closing time requirement

 

 

640

 

 

 

 

 

Send Inquiry

whatsapp

Phone

E-mail

Inquiry